Home About company Pumps Membrane separation Aerators Water
desinfection
Planning
 
 

VGUV-D Series Sterilier

Designed UV DOSAGE IS 40mj/cm2 to ensureno less than 99.9% effectivity of sterilizing rate for drinking water, which is in accordance with Title 55 standard, NSF of USA.

To improve the result of the disinfection and use the healthy drinking, the indexes of the incoming water into disinfector have to reach the following values:

Hardness < 7GRANS
Totaliron < 0.3ppm
HS < 0.05ppm
TSS < 10ppm

Manganese Content<0.05ppm
Turbidity < 5NTU
Chromaticity < 15 °C
PH = 6.5--9.5

 


Data sheet of VGUV-D Series

Model Rated flow rate
(GPM T/Hr)
Power
(W)
Power supply
(V/Hz)
Light/Sound
Warning
Diameter of water
inlet/outlet (Inch)
Dimensions
(mm)
VGUV-D01 1GPM/0.23T/Hr 8 220V/50Hz Yes 1/4" 285×37×52
VGUV-D02 2GPM/0.45T/Hr 14 220V/50Hz Yes 1/4" 350×63×113
VGUV-D06 6GPM/1.35T/Hr 25 220V/50Hz Yes 1/2" 505×63×113
VGUV-D12 12GPM/2.7T/Hr 39 220V/50Hz Yes 3/4" 910×63×113
VGUV-D25 24GPM/5.5T/Hr 80 220V/50Hz Yes 1.25" 910×159×289
VGUV-D36 35GPM/8.0T/Hr 100 220V/50Hz Yes 1.25" 1216×159×289
VGUV-D45 44GPM/10T/Hr 150 220V/50Hz Yes 1.25" 1600×159×289

NOTES:

1.Hydraulic-Pressure Resistance capability for all model is 0.7Mpa.
2.304 stainless steel is standard material for all models of sterilizer, 316L for option on customers request.
3.Out-screw connecting way is standard for single-lamp series, interior-lamp series, interior-screw of flange connecting way for option on customers request.
4.UV lamps with radiation output of 185 nano-meter wave-length are also provided by us, for TOC degradation for Super-purified water treatment.
5.Rights reserved for production specification modification without informed in advance.